Voltage drop: why cable distance matters
Use the free cable calculator to compare current, one-way length and AC or DC supply before choosing a cable size.
Open the free cable calculator →Measure the right length
The calculator asks for the one-way cable distance. DC and single-phase circuits have outgoing and return conductors; three-phase circuits use a different calculation. Enter the correct supply so the same length is not accidentally counted twice or treated as the wrong circuit.
Ampacity and voltage drop are separate checks
A cable can carry the current thermally yet lose too much voltage along a long route. Compare both results and the proposed protection. Installation method, insulation, ambient temperature, grouping and the applicable local rules can require a larger size than a simple distance calculation suggests.
Try a real comparison
Start with a 12 V DC circuit at 30 A over five metres, then compare the result at 24 V for a load drawing the same power. Current changes with voltage: do not keep 30 A and assume the two cases represent the same appliance. Use the editable inputs to test your own case.
These tools support planning and discussion. An installer must check equipment ratings, protective devices, local requirements and the installation itself before work begins.