Battery capacity: compare Ah, kWh and usable energy

Understand battery sizing for solar and backup: voltage, amp-hours, usable capacity, autonomy and charging all matter.

Size a battery within a solar plan →

Compare energy at the same voltage

Nominal energy in kWh is approximately voltage × amp-hours ÷ 1,000. A 12 V 100 Ah battery stores about 1.2 kWh nominally; the same 100 Ah at 48 V is about 4.8 kWh. These are arithmetic examples, not claims about the usable capacity of a particular battery.

Choose the backup duration first

List the essential loads and how long each must run without charging. The usable fraction of a battery, inverter losses, temperature and discharge limits reduce what reaches the loads. More battery capacity also needs a realistic way to recharge; adding storage alone does not increase winter solar production.

Check the battery as part of a system

WireTheSun considers battery sizing within the solar planning flow. Review voltage, capacity and the number of batteries rather than assuming a number of Ah fits every installation. Your installer must confirm BMS limits, inverter compatibility, fuses, cable ratings and charging settings.

These tools support planning and discussion. An installer must check equipment ratings, protective devices, local requirements and the installation itself before work begins.